You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
224 lines
6.4 KiB
224 lines
6.4 KiB
5 years ago
|
/*
|
||
|
SCP1000 Barometric Pressure Sensor Display
|
||
|
|
||
|
Serves the output of a Barometric Pressure Sensor as a web page.
|
||
|
Uses the SPI library. For details on the sensor, see:
|
||
|
http://www.sparkfun.com/commerce/product_info.php?products_id=8161
|
||
|
http://www.vti.fi/en/support/obsolete_products/pressure_sensors/
|
||
|
|
||
|
This sketch adapted from Nathan Seidle's SCP1000 example for PIC:
|
||
|
http://www.sparkfun.com/datasheets/Sensors/SCP1000-Testing.zip
|
||
|
|
||
|
Circuit:
|
||
|
SCP1000 sensor attached to pins 6,7, and 11 - 13:
|
||
|
DRDY: pin 6
|
||
|
CSB: pin 7
|
||
|
MOSI: pin 11
|
||
|
MISO: pin 12
|
||
|
SCK: pin 13
|
||
|
|
||
|
created 31 July 2010
|
||
|
by Tom Igoe
|
||
|
*/
|
||
|
|
||
|
#include <Ethernet2.h>
|
||
|
// the sensor communicates using SPI, so include the library:
|
||
|
#include <SPI.h>
|
||
|
|
||
|
|
||
|
// assign a MAC address for the ethernet controller.
|
||
|
// fill in your address here:
|
||
|
byte mac[] = {
|
||
|
0xDE, 0xAD, 0xBE, 0xEF, 0xFE, 0xED
|
||
|
};
|
||
|
// assign an IP address for the controller:
|
||
|
IPAddress ip(192, 168, 1, 20);
|
||
|
IPAddress gateway(192, 168, 1, 1);
|
||
|
IPAddress subnet(255, 255, 255, 0);
|
||
|
|
||
|
|
||
|
// Initialize the Ethernet server library
|
||
|
// with the IP address and port you want to use
|
||
|
// (port 80 is default for HTTP):
|
||
|
EthernetServer server(80);
|
||
|
|
||
|
|
||
|
//Sensor's memory register addresses:
|
||
|
const int PRESSURE = 0x1F; //3 most significant bits of pressure
|
||
|
const int PRESSURE_LSB = 0x20; //16 least significant bits of pressure
|
||
|
const int TEMPERATURE = 0x21; //16 bit temperature reading
|
||
|
|
||
|
// pins used for the connection with the sensor
|
||
|
// the others you need are controlled by the SPI library):
|
||
|
const int dataReadyPin = 6;
|
||
|
const int chipSelectPin = 7;
|
||
|
|
||
|
float temperature = 0.0;
|
||
|
long pressure = 0;
|
||
|
long lastReadingTime = 0;
|
||
|
|
||
|
void setup() {
|
||
|
// start the SPI library:
|
||
|
SPI.begin();
|
||
|
|
||
|
// start the Ethernet connection and the server:
|
||
|
Ethernet.begin(mac, ip);
|
||
|
server.begin();
|
||
|
|
||
|
// initalize the data ready and chip select pins:
|
||
|
pinMode(dataReadyPin, INPUT);
|
||
|
pinMode(chipSelectPin, OUTPUT);
|
||
|
|
||
|
Serial.begin(9600);
|
||
|
|
||
|
//Configure SCP1000 for low noise configuration:
|
||
|
writeRegister(0x02, 0x2D);
|
||
|
writeRegister(0x01, 0x03);
|
||
|
writeRegister(0x03, 0x02);
|
||
|
|
||
|
// give the sensor and Ethernet shield time to set up:
|
||
|
delay(1000);
|
||
|
|
||
|
//Set the sensor to high resolution mode tp start readings:
|
||
|
writeRegister(0x03, 0x0A);
|
||
|
|
||
|
}
|
||
|
|
||
|
void loop() {
|
||
|
// check for a reading no more than once a second.
|
||
|
if (millis() - lastReadingTime > 1000) {
|
||
|
// if there's a reading ready, read it:
|
||
|
// don't do anything until the data ready pin is high:
|
||
|
if (digitalRead(dataReadyPin) == HIGH) {
|
||
|
getData();
|
||
|
// timestamp the last time you got a reading:
|
||
|
lastReadingTime = millis();
|
||
|
}
|
||
|
}
|
||
|
|
||
|
// listen for incoming Ethernet connections:
|
||
|
listenForEthernetClients();
|
||
|
}
|
||
|
|
||
|
|
||
|
void getData() {
|
||
|
Serial.println("Getting reading");
|
||
|
//Read the temperature data
|
||
|
int tempData = readRegister(0x21, 2);
|
||
|
|
||
|
// convert the temperature to celsius and display it:
|
||
|
temperature = (float)tempData / 20.0;
|
||
|
|
||
|
//Read the pressure data highest 3 bits:
|
||
|
byte pressureDataHigh = readRegister(0x1F, 1);
|
||
|
pressureDataHigh &= 0b00000111; //you only needs bits 2 to 0
|
||
|
|
||
|
//Read the pressure data lower 16 bits:
|
||
|
unsigned int pressureDataLow = readRegister(0x20, 2);
|
||
|
//combine the two parts into one 19-bit number:
|
||
|
pressure = ((pressureDataHigh << 16) | pressureDataLow) / 4;
|
||
|
|
||
|
Serial.print("Temperature: ");
|
||
|
Serial.print(temperature);
|
||
|
Serial.println(" degrees C");
|
||
|
Serial.print("Pressure: " + String(pressure));
|
||
|
Serial.println(" Pa");
|
||
|
}
|
||
|
|
||
|
void listenForEthernetClients() {
|
||
|
// listen for incoming clients
|
||
|
EthernetClient client = server.available();
|
||
|
if (client) {
|
||
|
Serial.println("Got a client");
|
||
|
// an http request ends with a blank line
|
||
|
boolean currentLineIsBlank = true;
|
||
|
while (client.connected()) {
|
||
|
if (client.available()) {
|
||
|
char c = client.read();
|
||
|
// if you've gotten to the end of the line (received a newline
|
||
|
// character) and the line is blank, the http request has ended,
|
||
|
// so you can send a reply
|
||
|
if (c == '\n' && currentLineIsBlank) {
|
||
|
// send a standard http response header
|
||
|
client.println("HTTP/1.1 200 OK");
|
||
|
client.println("Content-Type: text/html");
|
||
|
client.println();
|
||
|
// print the current readings, in HTML format:
|
||
|
client.print("Temperature: ");
|
||
|
client.print(temperature);
|
||
|
client.print(" degrees C");
|
||
|
client.println("<br />");
|
||
|
client.print("Pressure: " + String(pressure));
|
||
|
client.print(" Pa");
|
||
|
client.println("<br />");
|
||
|
break;
|
||
|
}
|
||
|
if (c == '\n') {
|
||
|
// you're starting a new line
|
||
|
currentLineIsBlank = true;
|
||
|
}
|
||
|
else if (c != '\r') {
|
||
|
// you've gotten a character on the current line
|
||
|
currentLineIsBlank = false;
|
||
|
}
|
||
|
}
|
||
|
}
|
||
|
// give the web browser time to receive the data
|
||
|
delay(1);
|
||
|
// close the connection:
|
||
|
client.stop();
|
||
|
}
|
||
|
}
|
||
|
|
||
|
|
||
|
//Send a write command to SCP1000
|
||
|
void writeRegister(byte registerName, byte registerValue) {
|
||
|
// SCP1000 expects the register name in the upper 6 bits
|
||
|
// of the byte:
|
||
|
registerName <<= 2;
|
||
|
// command (read or write) goes in the lower two bits:
|
||
|
registerName |= 0b00000010; //Write command
|
||
|
|
||
|
// take the chip select low to select the device:
|
||
|
digitalWrite(chipSelectPin, LOW);
|
||
|
|
||
|
SPI.transfer(registerName); //Send register location
|
||
|
SPI.transfer(registerValue); //Send value to record into register
|
||
|
|
||
|
// take the chip select high to de-select:
|
||
|
digitalWrite(chipSelectPin, HIGH);
|
||
|
}
|
||
|
|
||
|
|
||
|
//Read register from the SCP1000:
|
||
|
unsigned int readRegister(byte registerName, int numBytes) {
|
||
|
byte inByte = 0; // incoming from the SPI read
|
||
|
unsigned int result = 0; // result to return
|
||
|
|
||
|
// SCP1000 expects the register name in the upper 6 bits
|
||
|
// of the byte:
|
||
|
registerName <<= 2;
|
||
|
// command (read or write) goes in the lower two bits:
|
||
|
registerName &= 0b11111100; //Read command
|
||
|
|
||
|
// take the chip select low to select the device:
|
||
|
digitalWrite(chipSelectPin, LOW);
|
||
|
// send the device the register you want to read:
|
||
|
int command = SPI.transfer(registerName);
|
||
|
// send a value of 0 to read the first byte returned:
|
||
|
inByte = SPI.transfer(0x00);
|
||
|
|
||
|
result = inByte;
|
||
|
// if there's more than one byte returned,
|
||
|
// shift the first byte then get the second byte:
|
||
|
if (numBytes > 1) {
|
||
|
result = inByte << 8;
|
||
|
inByte = SPI.transfer(0x00);
|
||
|
result = result | inByte;
|
||
|
}
|
||
|
// take the chip select high to de-select:
|
||
|
digitalWrite(chipSelectPin, HIGH);
|
||
|
// return the result:
|
||
|
return(result);
|
||
|
}
|